Olympus Exera II CV-180 HDTV Video Processor

$7000

For Sale: Refurbished Olympus CV-180 HD Processors

Certified Pre-Owned Used Olympus CV-180 Video System Completely Refurbished with 24 mth warranty.

  • Equipped with high-resolution HDTV and Narrow Band Imaging (NBI) capabilities to provide the best possible image quality for enhancing observation of capillaries and mucosal tissues
  • Compatible with the full range of endoscopes from EVIS 100, 130, 140, 160 and 180 series
  • HD/SD SDI output for high-quality video image transfer
  • Automatic Iris eliminates the need for switching between Peak and Average
  • Electronic structural enhancement highlights minute details without increasing noise
  • Still images can be stored on xD cars via the PC card adapter

Specifications:

  • Width:   38.2 cm
  • Height: 9.1 cm
  • Length: 49.0 cm
  • Weight: 10.5 kg

Equipped with high-resolution HDTV imaging capability to assure the best-possible image quality for endoscopy and laparoscopy. This enables enhanced observation of capillaries.
Compatible with EVIS 100/130/40 Series and EVIS EXERA™ 160 Series scopes as well as bronchoscopes and surgical endoscopes (EndoEYE™, 1CCD/3CCD camera head, and VISERA™ videoscopes).
Narrow Band Imaging™ (NBI) to enhance the visibility of fine capillaries and the mucosal tissues in the GI tract.
Two types of structure enhancement are available — the original Type A for observation of larger mucosal tissues with high contrast, and the new Type B for observation of smaller tissues, such as capillaries.
Electronic magnification enlarges moving or still images at the touch of a button by 1.2x or 1.5x with no loss of quality.
Convenient recording of both still and moving images on xD cards or digital video cassettes using remote control switches.
HD/SD SDI output for deterioration-free images.
Automatic Iris eliminates the need for switching between Peak and Average required in conventional manual adjustment.
Picture-in-picture display for any combination of endoscopic, fluoroscopic, ultrasound, laparoscopic, and images from the endoscope position detecting unit.
Convenient index display for documentation.
Scope ID™ function for easy endoscopy suite management and for next-generation system expansion.

Experience the new standard in Endoscopic imaging with this advanced HDTV-compatible video processor.

* Equipped with high-resolution HDTV imaging capability to assure the best-possible image quality for endoscopy and laparoscopy. This enables enhanced observation of capillaries.
* Compatible with EVIS 100/130/40 Series and EVIS EXERA™ 160 Series scopes as well as bronchoscopes and surgical endoscopes (EndoEYE™, 1CCD/3CCD camera head, and VISERA™ videoscopes).
* Narrow Band Imaging™ (NBI) to enhance the visibility of fine capillaries and the mucosal tissues in the GI tract.
* Two types of structure enhancement are available — the original Type A for observation of larger mucosal tissues with high contrast, and the new Type B for observation of smaller tissues, such as capillaries.
* Electronic magnification enlarges moving or still images at the touch of a button by 1.2x or 1.5x with no loss of quality.
* Convenient recording of both still and moving images on xD cards or digital video cassettes using remote control switches.
* HD/SD SDI output for deterioration-free images.
* Automatic Iris eliminates the need for switching between Peak and Average required in conventional manual adjustment.
* Picture-in-picture display for any combination of endoscopic, fluoroscopic, ultrasound, laparoscopic, and images from the endoscope position detecting unit.
* Convenient index display for documentation.
* Scope ID™ function for easy endoscopy suite management and for next-generation system expansion.

M.D. Endoscopy offers the following warranty Terms and Conditions for all equipment purchased and complete refurbishment repairs:

The following warranty terms will last for 24-months from the date of purchase.

Coverage shall include all parts (24-months) and labor (24-months) incurred to the customer from any manufacturer or replacement part defects.

The customer shall be responsible for parts and labor charges for any and all repairs determined by M.D. Endoscopy to be caused by misuse, mishandling, excessive wear & tear, or accidental damage.

The customer shall be responsible for any and all shipping charges incurred, if equipment is determined to be damaged through misuse or mishandling.

Warranty shall be null and void if determined by M.D. Endoscopy that the equipment has been sent to an outside vendor for parts or labor during the warranty period.

Warranty shall also be voided should the equipment be sold to another individual or company.

EXAMPLES of client misuse, mishandling, or accidental damage include:

  1. Puncturing the scopes internal tubing with biopsy forceps, cleaning brush, or other items.
  2. Dropping or knocking equipment.
  3. Flooding of scope or equipment through failure to adhere to leak test procedures or misuse.
  4. Instruments closed or slammed in cabinet, doorway, or similar structures.

THERE MAY BE FURTHER INSTANCES OF ACCIDENTAL DAMAGE NOT LISTED ABOVE, IN WHICH THE WARRANTY WILL NOT COVER PARTS OR LABOR CHARGES, M.D. Endoscopy RESERVES THE RIGHT TO MAKE THIS DETERMINATION.

Warranty agreement shall begin on date of client purchase and shall run concurrently for 24 months, including weekends and holidays until expiration.

Request More Info Add to Cart