Olympus EVIS X CV-1500 Video Processor and Light Source
Request a Quote
-Return Policy: 7-Day Satisfaction Guarantee.
-Condition: Demo | Certified Pre-Owned | Refurbished
-Availability: Limited
For Sale: Refurbished Olympus X1 CV-1500 HD Video Processor and Light Source
CERTIFIED PRE-OWNED USED OLYMPUS CV-1500 VIDEO SYSTEM COMPLETELY REFURBISHED WITH 24 MONTH WARRANTY.
The EVIS X1 CV-1500 Video System Center combines video processor and LED light source in one box, resulting in a compact and lightweight design. The CV-1500 features multiple special observation modes that support physicians in every step during endoscopic procedures.
Key Benefits
In addition to conventional white light and NBI™ (Narrow Band Imaging™) technology, the CV-1500 offers three other powerful enhanced observations to improve diagnostic and therapeutic capability:
- TXI™ Technology (Texture & Color Enhancement Imaging) optimizes the structure, color tone and brightness of the mucosal surface.
- RDI™ Technology (Red Dichromatic Imaging) improves visibility of deep blood vessels and bleeding points.
- BAI-MAC™ (Brightness Adjustment Imaging with MAintenance of Contrast) technology improves brightness in darker portions of the image.
TXI, RDI, NBI and BAI-MAC technologies are not intended to replace histopathological sampling as a means of diagnosis.
With One-Touch Connector and no need for white balance adjustment,3 setup is simplified, with the aim of streamlining workflow and accelerating procedure time. Touch-sensitive panel facilitates instinctive operation, while convenient functions like Pre-freeze and MyCV mode assist in creating a user-friendly working environment. Downtime may be reduced thanks to the use of LED bulbs that have been designed to last years without needing replacement.
Complications from an endoscopic procedure may include, but are not limited to, reaction to sedation, bleeding, perforation, infection, and/or pancreatitis. Never apply the endoscope connected to the CV-1500 video system center to the heart or any area near the heart; leakage current from this Type BF-applied part may be dangerous and cause ventricular fibrillation or otherwise seriously affect the cardiac function of the patient. Improper disinfection of the video system center may result in operator and/or patient infection. For complete indications, contraindications, warnings and cautions, please reference the Instructions for Use (IFU) that accompanied the EVIS X1™ CV-1500 video system center.
MD Endoscopy Warranty Terms & Conditions for Equipment Purchases | Complete Refurbishment Repairs:
The following warranty terms will last for 24-months from the date of purchase.
EXAMPLES of client misuse, mishandling, or accidental damage include:
THERE MAY BE FURTHER INSTANCES OF ACCIDENTAL DAMAGE NOT LISTED ABOVE, IN WHICH THE WARRANTY WILL NOT COVER PARTS OR LABOR CHARGES, MD Endoscopy RESERVES THE RIGHT TO MAKE THIS DETERMINATION.
Warranty agreement shall begin on date of client purchase and shall run concurrently for 24 months, including weekends and holidays until expiration.
Add a product review
- Case with Key
- Air/Water & Suction Valve
- Water Resistant Soaking Cap
- Cleaning Brushes | Connectors
- Operators | Reprocessing Manuals
- 24-month Warranty Certificate
- Keyboard
- Water Bottle
- Video Connector | Pigtail (if applicable)
- RGB or SDI Monitor Cable
- Power Cords
- Photo Cable (if applicable)
- Printer Remote Cable (if applicable)
- Operators Manual
- 24-month Warranty Certificate
- All the above PLUS
- FREE Leak Tester
- FREE Shipping (US LOCATIONS)
- FREE Installation (US LOCATIONS)
- FREE Reprocessing | Cleaning In-service (US LOCATIONS)
- FREE "Go-Live" Procedure Day Assistance (US LOCATIONS)
- 24-month Warranty Certificate